Technical data - GAMMA 450
Wire length, single-sided processing min. | 60 mm |
Wire length, processing on both sides min. | 60 mm |
Wire length, processing on both sides (optional from) min. | 60 mm |
Wire length max. | 65000 mm |
Strip length side 1 min. | 0.1 mm |
Strip length side 1 max. | 29.5 mm |
Strip length side 2 min. | 0.1 mm |
Strip length side 2 max. | 29.5 mm |
Strip length, full stripping side 1 (blade in wire line) max. | 17.5 mm |
Strip length, full stripping side 2 (blade in wire line) max. | 17.5 mm |
Strip length, full stripping side 1 (blade next to wire line) max. | 35 mm |
Strip length, full stripping side 2 (blade next to wire line) max. | 35 mm |
Strip length, partial stripping side 1 (blade in wire line) max. | 16.5 mm |
Strip length, partial stripping side 2 (blade in wire line) max. | 16.5 mm |
Strip length, partial stripping side 1 (blade next to wire line) max. | 21 mm |
Strip length, partial stripping side 2 (blade next to wire line) max. | 35 mm |
Dependency of strip length | The strip length depends on the guide tube selected, on the outer diameter of the wire and on diverse functions such as cutting pulled strands and quality monitoring (Q12XX). Strip length for half stripping without cutting pulled strands, without quality monitoring (Q12XX) and with a short guide tube. |
Wire outer diameter max. | 3.9 mm |
Wire cross section min. | 0.13 mm² |
Wire cross section max. | 4 mm² |
Noise level (without crimp modules) max. | 75 dB |
Electrical connection | 3 × 208 – 480V 50/60Hz; 5.6kVA |
Electrical connection (optional) | 3×400V, 50/60Hz, neutral required, 5.6kVA |
Minimum permissible cross section of connection lines | 94 psi bis 104 °F / 87 psi ab 104 °F in |
Minimum permissible cross section of connection lines | 94 psi bis 104 °F / 87 psi ab 104 °F mm² |
Compressed-air connection | 5 – 8 bar |
Air consumption with wire length of 500mm (19.7inch) (Crimp/Crimp) | 5.9 m³/h |
Air consumption with wire length 500mm & 19.7 inch (Seal Crimp/Seal Crimp) | 8.4 m³/h |
Recommended operating pressure ±0.5bar/7.25psi | 6 ±0.5 bar |
Operation outside the recommended operating pressure | Non-compliance with the recommended operating pressure can restrict the proper functioning of peripheral devices. Please also observe the technical data for peripheral devices. |
Weight (approx.) | 920 kg |
Weight (incl. 2 crimp modules and 2 seal modules) approx. | 920 kg |
Length | 3388 mm |
Length with basic module 2m/78.74 inch | 3388 mm |
Length with basic module 4m/187.48 inch | 5333 mm |
Width | 1445 mm |
Height (with safety cover closed) | 1775 mm |
Height (with safety cover open) | 2775 mm |
Ambient temperature min. | 10 °C |
Ambient temperature max. | 45 °C |
Humidity, non-condensing | 30 - 90 % |
Hard, tough wires | In the case of extremely hard, ductile or thick-stranded wires, processing might not be possible even within the cross section range. In case of doubt, Komax will be happy to provide processing samples of your wires. |